Negative Pressure Rooms for Hospitals and Emergency Rooms

Prefabricated cleanroom components allow faster construction of sealed and HEPA filtered triage areas for emergency rooms and hospitals. New generation fan filtration units with reverse blowers and HEPA filters exhaust clean air externally and curb airborne contamination or viruses such as COVID-19.

Negative vs Positive Pressure Hospital Rooms

For a negative pressure room, the sum of the mechanically exhausted air must exceed the sum of the mechanically supplied air. The result is a negative pressure differential. How does one decide on the best approach to containment areas in healthcare systems when both positive and negative air pressure areas are needed?

Single Pass Design

Recirculating Design

Negative Pressure

Softwall Containment

Negative Pressure Hospital Rooms

Rooms for containment of infectious diseases, viruses and pathogens have neutral or negative pressure depending on the risk classification. Negative pressure hospital rooms prevent air contamination from leaving the envelope of the enclosure by evacuating air faster than introduced.

A negative or positive pressure area may consist of multiple sealed and partitioned structures. An outer structure, called an anteroom, allows for a cascading increase or decrease in pressure between the interior and exterior walls.

Hardwall Triage Structures and Ceilings

Each containment structure includes integrated hardware for a T-grid ceiling system. The T-grid ceiling system is capable of self-supporting the ceiling mount fan filter systems. The number of fan filters is customized based on the size of the area and ceiling height.

Air Change Requirements for Hospital Containment Zones

Generally, negative pressure rooms for infectious disease and aerosol containment require at least 12 air changes per hour. The CFU of each fan filter is either variable or switch toggled. The number of fan filters, CFUs per blower, input/output airflow, and room size will dictate the total room air exchange rate. There are reasons to increase the number of fan filters instead of ramping up CFU including max efficiency curves, system redundancy, filter lifetime, and noise floor.

CDC Infectious Disease Control Negative Pressure Air Change Requirements (2003)

  • Pressure differential of 2.5 Pa (0.01-in. water gauge) measured at the door between patient room and anteroom
  • Air volume differential >125 CFM, depending on anteroom airflow direction (i.e., pressurized versus depressurized)
  • Anteroom airflow patterns (i.e., anteroom is pressurized in the top and middle panels, and depressurized in bottom panel).

“This isolation area receives numerous air changes per hour (ACH) (≥12 ACH for new construction as of 2001; ≥6 ACH for construction before 2001), and is under negative pressure, such that the direction of the airflow is from the outside adjacent space (e.g., corridor) into the room.”

Guidelines for Environmental Infection Control in Health-Care Facilities (2003)

Softwall Curtain Containment with Negative Airflow Exhaust

triage area curtains

Not all scenarios need floor to ceiling containment structures. Hybrid approaches include softwall curtain enclosures, air evacuation, and clean corridor designs which can either create air buffer zones and containment structures.

Hybrid approaches such as curtain enclosures do not provide a qualified negative pressure containment, however, when calibrated to the proper ACH (air changes per hour) will provide a neutral air barrier and log reductions in airborne virus levels.

Overall, these are highly effective safety barriers built for your location to mitigate the transmission of dangerous airborne contagions. This cost-effective vinyl separation curtain is suspended from the ceiling and is quickly customized to perfectly fit your space and keep your employees’ health uncompromised.

Hospital Negative Pressure Room Requirements

The air gap between two separate rooms on a shared wall is measured by water channel ( WC or inches of water). For most negative pressure rooms the WC is typically 0.01 – 0.03-inch water gauge (in. w.g.)
or +-2.5 Pascals (Pa) between each partition of lower or higher pressure (including the outside air)

Air balancing within a containment curtain is less complex than a sealed, hardwall room, but also less effective. A single fan filter unit within an immediate containment is usually capable of log reductions in airborne virus levels. The advantage of containment curtains for hospitals is that patient areas already have integrated slide curtain hardware.

Read: Modifying Positive Pressure Rooms for Negative Pressure

Negative Pressure Room Scenarios:

  • Airborne contagions
  • Opportunistic pathogens and viruses
  • Hazardous or toxic waste saturation/fumes
  • Infectious quarantine or isolation

Positive pressure triage rooms are effective when bacterial cleanliness and infection control is the primary concern. For example, a temporary mass trauma center, field hospital, burn unit, or temporary intensive care unit for compromised hosts.

Positive Pressure Containment Room Scenarios:

  • Sterile procedures
  • Immunocompromised patient rooms (e.g., hematopoietic stem cell transplant or
  • Solid organ transplant procedure rooms) and orthopedic operating rooms.

Mobile Negative Pressure Filtration Systems

We provide transportable air filtration solutions for healthcare isolation rooms and negative pressure air handling.

An integrated fan blower, HEPA filter, and motor are affixed to a mobile cart in which a single ceiling-mounted filter can evacuate enough to provide negative pressure for rooms of up to 400 sq. ft.

The cradle is assembled and outfitted with 2″ castors and breaks for easy movement.

The FFU’s (fan filter units) are actively powered and fitted with a power cord, integrated hood, and 10″ – 12″ duct-collar adapter. The collar adapter connects the fan filter to most standard HVAC return exhaust systems if possible, to an outside area, or to a parallel space if deemed appropriate.

HEPA Fan Filter Units

CleanPro® Cleanroom Fan Filter Units

CleanPro® self-contained 99.99% efficient HEPA or 99.9995% efficient ULPA-equipped fan filter units are available for a variety of critical applications.

Temporary Surge Areas

The appropriate configuration for your facility must consider state and local authority such as fire, health, and building codes. According to the State of MN (2016) The three options for creating a temporary surge area using HEPA filters are similar to Types #1 and #2 of TNPI for a patient room. 

  • Each of these options should be used in conjunction with a safe area (anteroom). 
  • Discharging through a window Discharging to an adjacent space Discharging to a return air system 
  • These three options may be used in combination to achieve the desired pressure differential.

Get Help with an Emergency Room Triage Design or Engineering Layout

PAC (that’s us) is a provider of variable filtration and containment solutions.

Design

PAC works directly with customers and manufacturers for end-to-end engineering of containment structures, filtration systems, and necessary installation hardware. We handle all of the upfront engineering for manufacturing including the final form, fit, and function of the on-site system.

Installation

For smaller containment systems, especially those in hazardous or high-risk areas, most facilities will handle the installation internally via the facilities team or familiar contractor. These systems are extremely simple to erect and wire with basic tools and hardware, thus virtually zero modification is required for on-site installation.

Our existing cleanroom walls could be repurposed to build isolated patient partitions in medical triage tents, intake, screening, or temporary care areas.

  • Customized Dimensions & Features
  • Dimensions are customized to your space.
  • Easily integrate windows and openings appropriate for your business.
  • Hygienic & Functional Design
  • Prevent physical contact while maintaining normal interactions such as barcode scanning. 
  • Tri-panel design mitigates airborne transmission from coughing or sneezing.
  • Easy to Clean
  • Hygienic aluminum and acrylic material can be cleaned using wipes, bleach or disinfectant.

Negative Pressure Rooms for Hospitals

Production Automation Corporation (PAC) is a factory-direct cleanroom supplier for environments, supplies, apparel, and furniture.

Every PAC product is backed by dedicated customer service, sales support, and in-house specialists.

Need help with a technical manufacturing solution? We’re the specialists in your back pocket.

 

PAC GCLID:    
Lead Source:    
Source Page:    
Source Website: *    
What Can We Help You With?    
Additional Questions or Information:    
First Name: *    
Last Name: *    
Email: *    
Phone Number: *    
Company Name:    
Street Address:    
City:    
State:    
Zip:    

* Required fields. You will not be opted into promotional e-mails.

Share this Article:

Facebook
Twitter
LinkedIn
Reddit
Email
Print
Mitch Walleser

Mitch Walleser

Mitch is a contributing writer for Production Automation Corporation. PAC is a factory-direct distributor of products and environmental solutions for industrial and critical requirements within electronics, medical device, life science, pharmaceutical, and general manufacturing industries. Mitch has worked with manufacturing engineers, in-house specialists, and factory experts to highlight and uncover manufacturing solutions. His background includes 3D printing, electronics, and cleanroom manufacturing.

Search Posts

About Production Automation

Production Automation Corporation (that’s us) is an essential business supplier for medical device, cleanroom, and general manufacturing industries.

All products featured on the PAC blog are available through the www.gotopac.com webstore. Online orders are shipped and fulfilled Monday – Friday from PAC warehouses in California, Minnesota, and Texas.

Production Automation Corporation (PAC) stands 100% behind a product catalog of over 40,000 products, which includes support for factory warranties, value added services, and returns. Get help from a PAC sales rep during business hours via email, phone, or live chat.

Shop Online: www.gotopac.com
Toll Free: (888) 903-0333
Email: [email protected]
Office Hours: 8am - 5pm CST