Question: What Class clean room is required to manufacture FDA approved N95 masks, isolation gowns, surgical masks, etc?
There are various benchmarks for FDA approved products such as surgical N95 masks and surgical isolation gowns. Before we get to the answer, lets look more closely at what types of products and devices are FDA regulated.
Does the FDA Regulate PPE?
Some PPE items are regulated by the FDA, others are not. Naturally, any item label, approved, and specified as a medical device is approved and regulated by the FDA. Some N95 mask are certified for healthcare and surgical use and thus require more elaborate production controls. Further, some face masks require “cleanroom rated” materials which will not shed lint or fibers.
Does the FDA Regulate N95 Masks?
The FDA regulates products such as surgical N95 respirators and surgical-grade gowns. (Considered medical devices). Masks and PPE for non-medical purposes are not medical devices and are not regulated by the FDA.
FDA Cleanroom Standards for PPE Production
In general, the FDA does not provide specific guidance on cleanroom build specifications or requirements. They will defer to USP or CGMP standards. Most USP and CGMP cleanroom build requirements are based on ISO 14644-1, a baseline where we start all of our cleanroom builds.
Cleanroom Requirements for Sterile vs Non Sterile Devices
Something like an intracavity device or other sterile medical device may require an ISO 5 cleanroom, whereas medical device packaging and other less sensitive processes are usually specified at ISO 7 or ISO 8.
Cleanroom ISO Class for Sterility Assurance
It really depends on how the final device will be classified, labeled, what it will be used for, and what degree of sterility assurance it requires (if any). For example, the desired Sterility Assurance Level (SAL) for garments to be used in sterile pharmaceutical manufacturing is 10^6, which translates into an assurance that a sterile garment has only one-in-one million probability of being non-sterile.
ISO class is just one aspect of delivering a production ready cleanroom. Sterile procedures normally demand cascading cleanroom suites of positive pressure, air quality monitoring, precise pressure differentials, aggressive cleaning regimens, and air tight seals.
Terminally Sterile Device Manufacturing
If you’re looking to manufacture anything terminally “sterile”, like sterile surgical gowns or masks, you’d spec an ISO 5 cleanroom at the least. (ISO 5 is the general standard of a “sterile” or aseptic workflow environment. For items that will be sterilized after production, an ISO 7 medical device cleanroom is a common benchmark.
Clean Rooms for Sterile Products
An ISO 5 room would be similar in nature to cleanrooms built under USP 797 (sterile) or USP 795 (non-sterile) standards. The room has a cascading suite of positive pressure rooms which start at an ISO 7 or 8 buffer / ante for gowning and product preparation, while the critical production processes are carried out in the interior ISO 5 room.
Assessing Cleanroom Requirements for Garment and Apparel Manufacturing
It’s crucial to assess the specific sensitivities of the product, size of the operation, and how clean/dirty the process is under working conditions. This is generally where project leads will reach out to a PAC cleanroom construction specialist, as we can deliver full turn-key cleanroom systems that are guaranteed to validate for all major industry benchmarks and compliance needs.
Production Automation Corporation (PAC) is an essential supplier of manufacturing equipment, supplies, and environmental controls.
We have face masks currently in stock at warehouses across the United States. As warehouse inventory is cycled and restocked, the exact specifications may vary. Stock levels change daily. Have questions? Post your comment below. (Sí, se habla español)
Procedural Masks
- 3 Layer Mask
- PP + Spunbond Layers
- No Latex
- No Fiberglass
- Ear Loops
- Soft Lining and Breathable
KN95
- Disposable non-surgical face masks.
- Designed for everyday civilian use.
- 95% filtration efficacy
- Filters out particles, dust, droplets, etc.
- 3rd-party tested and validated
- Comfortable ear loops
Disclaimer
The content provided is for informational purposes only. It does not constitute a recommendation for your facility or organization. This post serves as a general guideline and summary. Compliance requires temporal evaluation on a case-by-case basis according to state and federal law. The content herein, linked content, or other web content provided by Production Automation Corporation (PAC) makes no claims as to the final interpretations or implementation of regulatory documents provided by the FDA, State Board of Pharmacy, NIOSH, CDC, EPA, or United States Pharmacopoeia (USP). For this reason, PAC provides on-staff specialists who are available toll free (888) 903-0333 for consultation at no cost, no obligation.
Related Posts
-
Medical Device Cleanroom Construction Part 1: Walls and Installation
How is a medical device cleanroom built? Here's a component-by-component guide to ISO Class 7 cleanroom construction.
-
USP 800 Cleanroom Construction Hazardous Compounding: Options and Alternatives
There are a few options available to cleanroom facilities who require new upgrades for USP 800 compliance. The best option will depend on the variables of the facility and cleanroom in question. Option A: Convert…
-
USP 800 Cleanroom Design - Negative Pressure Changes and Requirements
What equipment and engineering controls do USP 800 cleanrooms require? What types of storage and monitoring systems will I need?
-
Cleanroom Wipe Testing Standards for ASTM, IEST & ISO Organizations
ISO cleanroom wipe classification is important, but is it enough? A clean room wipe selection criteria should meet baseline particulate shed thresholds for the end-user environment. Like any cleanroom rated product, cleanroom wipe manufacturers qualify…
-
Medical Device Cleanroom Build Part 7: Cleanroom Validation Steps | Processes
What are the steps for medical device cleanroom validation? Cleanroom validation ensures cleanroom construction meets the performance standards set forth during cleanroom planning, cleanroom installation, and cleanroom calibration.
-
Medical Device Cleanroom Construction Part 6: Pressure Differentials, Humidity and Temperature Calibration
The central controller integrates the data from both the thermostats, fan filter processors, and room-side environmental sensors. Fan filter speed is then adjust by each group to achieve the specified room pressure while at ideal…
-
Medical Device Cleanroom Construction Part 5: HVAC Balancing & Calibration
Before cleanroom validation, a cleanroom requires mechanical calibration. HVAC calibration first ensures that the room meets the performance parameters which would deliver the expected results during final ISO validation, such as differential pressure, air change…
-
Cleanroom Fan Filter Testing and Maintenance - HEPA Filter Replacement and Troubleshooting
How do I know when to replace my cleanroom HEPA air filters? How do I test a cleanroom HEPA filter? What are the best practices for cleanroom HEPA filter replacement?
-
Medical Device Cleanroom Construction Part 3: Fan Filter Units - Ceiling Grids
In this post, we overview technical considerations for clean room fan filter unit selection, installation, and features. You'll learn how PAC approaches design and configuration of cleanroom HEPA filter units and fan filter housing specifications.…
-
Medical Device Cleanroom Construction Part 2: Doors, Electrical, and Layout
In medical device cleanrooms, a common configuration is an ISO 8 gowning room and ISO 7 primary production area. A cascading air flow design and positive pressure HVAC calibration move the cleanest air at the…