Regulations, Cost, Location, Size, Performance – How Do You Choose the Right Cleanroom?
Selecting a cleanroom for a new business or product is not a difficult process. There are many considerations and options, but focusing first on requirements will help make the decision-making process easier.
Cleanroom Selection Criteria
Government regulations, ISO guidelines, or customer requirements are the first consideration in selecting the right cleanroom. For example, government regulation USP 797 outlines specific requirements for the manufacture of pharmaceutical products, and ISO 14644-5:2004 guidelines specify basic requirements for cleanroom operation standards. Most often regulations of customer specifications will dictate the cleanliness of level or required rating, which provides a good starting point for choosing the right cleanroom.
Cost is an important consideration, especially if starting a new business or new product line. Prices can vary greatly from custom, fixed wall construction to modular, free-standing, soft wall, or hard wall prefabricated cleanroom systems. Fixed wall rooms are typically most expensive, with soft wall cleanrooms being the least expensive. Additionally, size, shape, configuration, and accessories will affect the overall cost.
The location of the cleanroom site within the existing building structure and the number of processes and workers in the cleanroom will determine the size and shape of the room.
In addition to meeting performance needs, many companies consider the visual aesthetics of a cleanroom very important, wanting to project a high-tech image with visual appeal to attract new customers.
Advantages of Modular Cleanrooms
Modular, free-standing cleanrooms have many distinct advantages over their fixed-wall counterparts. Using modular cleanrooms greatly reduces design, engineering, and construction time, thereby reducing costs. Since they are not an integral part of a larger structure, modular rooms can be taken down and moved to other facilities, or even sold as an asset. Fixed-wall cleanrooms do not have this flexibility.
Expanding modular cleanrooms can be easily accomplished by taking off a wall and adding another module. The prefabricated design allows the room to be expanded, relocated, or reconfigured into a different shape or made into multiple smaller rooms.
All air handling and filtration equipment modules are built into the modular room ceiling. Hook-ups for electrical and plumbing are engineered as part of the design.
The amount of time it takes to construct modular cleanrooms is much less than constructing a permanent walled structure. It can take several months to construct a fixed wall cleanroom because of the amount of design, engineering, and the various trades involved. However, a fairly sophisticated modular room can be constructed in a week or two. On-site assembly of modular cleanrooms is also less disruptive to surrounding operations in comparison to their fixed-wall counterparts.
Modular cleanroom systems offer potential tax advantages for businesses. They are not typically considered part of the building and can often be depreciated faster than built-in, fixed-wall cleanrooms. Tax consultants can provide specific tax advantage information.
PAC cleanroom specialists help you identify which components best suit for your application with respect to federal and organizational guidelines. Let’s connect you to one of our modular cleanroom solutions, or provide you with a free quote for a custom cleanroom.
Modular, Solid Wall Cleanroom Construction Considerations
There are two basic types of modular, solid wall cleanrooms: recirculating and non-recirculating. Product and process requirements will determine which type of room is best suited for a company’s needs.
Recirculating cleanrooms recirculate the air within the cleanroom and prevent it from mixing with the outside air, allowing for better control of the temperature and humidity. Air is recirculated back to the high-efficiency particulate absorbing (HEPA) filters located in the cleanroom’s ceiling. This is accomplished by using air return chambers in the room’s walls or through existing walls of the building. The recirculating cleanrooms will have less contamination loading on the HEPA filters because the system is recycling previously cleaned air. With less contamination loading, the filters will last longer and perform better.
Non-recirculating, sometimes called single pass rooms, draw in air from above the room into the ceiling HEPA filters. The filtered air is then blown into the cleanroom and exits through an approximate two-inch space located below the walls or through adjustable wall grills. Non-recirculating cleanrooms are less costly to construct than recirculating rooms due to the lack of return air duct-work.
Cleanroom Performance Considerations
Most businesses are aware of their cleanroom performance requirements because of customer, industry, or government specifications. These performances requirements identify the cleanroom class level required at a given state or condition. There are three levels of condition (states) for testing and characterizing the performance of cleanrooms: as-built, at-rest, and operational. Specific test methods for these three classifications are outlined in ISO 14644-3:2005.
Most cleanrooms are rated and sold in the as-built category- an empty room with the filter system running, but without workers and production equipment. However, adding workers and equipment will introduce contamination and affect the room rating. A cleanroom may rated ISO 6 at rest, but at ISO 7 during operation (See Table 1). To comply with performance requirements, the as-built empty room should be tested and benchmarked, followed by testing and documentation of the at-rest or operational states if not in compliance, corrective steps need to be taken. These steps can range from examining the production process and number of workers in the cleanroom, to testing the room’s air flow performance.
To ensure optimal cleanroom performance, air flow design and frequency or air changes should be evaluated. Cleanrooms are classified according to the number and size of particles permitted per volume of air in a specific amount of time. There is a relationship between cleanroom class ratings and the room’s air changes per hour. For a cleaner room rating, more air exchanges become necessary.
For example, a typical ISO 7 Class room will have 60-150 changes of air per hour, while an ISO 6 Class room will have 150-240 changes (See Table 2).
All areas within a cleanroom should have similar air changes during each hour to ensure required performance. For example, a cleanroom with only one air return or exit, located at the opposite end of the fan and filter, will produce stagnant air spots. This type of design causes air to flow almost horizontally across the room to the venting location, in a line-of-sight fashion. Areas of inadequate air movement retain higher levels of contamination. Adding or moving air returns will enable a more vertical and even air flow, improving overall air quality. The right balance of filter systems and air returns must be maintained to create positive air pressure inside the cleanroom. Positive air pressure produces an outward air movement, preventing the inflow of contaminates and assisting in expelling particles generated by workers and equipment.
Cleanroom air flow performance can be cost-effectively upgraded by adding fan-filter modules (FFM). For example, FFMs cover approximately 5-15% of an ISO 8 Class cleanroom ceiling. Upgrading to an ISO 7 Class cleanroom requires 15-25% ceiling coverage, and covering 25-40% of the ceiling changes the room to an ISO 6 Class (See Table 2).
Accessories for Modular Cleanrooms
To make a cleanroom fully functional, a variety of additional accessories, from lighting and doors to furniture and changing rooms, need to be considered. Accessories can be selected while working with the modular cleanroom company during the room design and specification phase.
Most cleanrooms have adjacent gowning areas where workers change into special garments, minimizing particulate contamination before entering the production area of the cleanroom. Some gowning rooms are equipped with air showers as a way to further reduce particulate contamination that might settle on the surface of a cleanroom garment. Some gowning rooms may have special benches for people to use while changing into boots, gloves, gowns, and masks.
Many companies may use the gowning room for transferring production material and equipment in and out of the clean environment. However, pass-through or double-door airlocks are more efficient and keep the introduction of particulate contamination to a minimum.
Specially produced cleanroom furniture and tools should be used because they are designed for a low particulate generation. For example, tables are smooth and sealed so they don’t shed particulates and can be easily wiped down.
Modular Cleanroom Location
The modular cleanroom location within a building is very important. Physical space, temperature/humidity, and cleanliness will affect selection decisions and overall project cost.
Most modular cleanrooms can be installed with as little as 25 inches of clearance over the inside clear height of the room on non-recirculating rooms, and about 30 inches with recirculating rooms.
A typical cleanroom should operate at about 66-70 degrees Fahrenheit to ensure a comfortable environment for workers wearing a garb such as lab coats, head coverings, gloves, and masks.
Non-recirculating cleanrooms provide better temperature control between the interior cleanroom and the surrounding building space. The room air does not mix with the external air and only requires cooling to compensate for the internal heat load. Processes requiring humidity control will require special environmental control systems and are usually only available with recirculating cleanrooms. Typically, systems are made just to add or just remove humidity depending on the surrounding environment.
On-Site Installation
Installation of a modular, hardwall cleanroom is quick and easy. With modular systems everything is prefabricated at the factory, so specialists are not needed to assemble the room, just local trades or internal people. It’s not uncommon to start a project on Monday and finish on Friday.
Maintenance Considerations
Regular cleanroom maintenance is very straightforward and is needed to ensure cleanroom performance and certification.
Interior surfaces are wiped down daily on a regular basis or before each shift using a solution of deionized water and 10% alcohol. The cleanroom floors are routinely mopped as well. Vertical surfaces, such as walls can be cleaned less frequently depending on product requirements. All contact points such as door handles and user-operated equipment should also be wiped down on a daily or shift basis, again, depending on process requirements.
HEPA filters have a pre-filter that needs to be changed regularly- depending on loading. The HEPA filter modules are fairly maintenance free, but are required to be certified every year. Additionally, proper air flow and leak checks are usually part of the regular certification for a cleanroom.
Certification of a cleanroom can be performed by either internal personnel or external companies. Most companies prefer an external, third-party firm to perform the certification, providing them with an independent analysis. Customer or product requirements may require independent certification.
Summary
Determining the right cleanroom for a new product or business requires balancing many selection aspects- from process requirements and cost, to performance and construction. The decision process is not complex, but a clear understanding of cleanroom requirements, regulations, operation, and available options will make cleanroom specification and design easier.
Production Automation wants to make choosing the right cleanroom as easy as possible. If you have any questions or concerns please contact us at 888-903-0333 or by email at [email protected].
Production Automation also offers a Hardwall or Softwall Cleanroom Quote Form to provide you with an accurate quote.
Get started:
Cleanroom Construction Products you can find them HERE
© Controlled Environments, Kevin Weist 2010
PAC cleanroom specialists provide engineering, construction, outfitting, and environmental solutions for casual and critical production environments.
We’ve developed a culture of specialists that assess your needs and solve your manufacturing problems. Solving the right problem starts with asking the right expert. How can we help?
Related Posts
-
Why is Modular Cleanroom Design A Huge Development?
Pre-engineered fabrication consolidates scheduling with minimal disruption and fewer variables. Difficult or expensive upgrades avoid overbearing noise, construction artifacts, and minimize if not eliminate the burden on facility staff for project management.
-
CleanPro® Softwall Cleanroom Curtains Installation
Softwall cleanroom curtains, sometimes referred simply as “plastic strips” yield ISO Class 10,000 level particle control with minimal construction. This customer required a custom softwall installation that integrated into their existing building structure CleanPro to…
- Quick Ship Hardwall Cleanrooms
Legend Quick Ship Series Hardwall Cleanrooms Ships within 5 business days of receiving order! Pre-engineered, modular design cleanrooms are cost effective without the inconvenience of conventional "stick-built" construction. Once Through Design Once-Thru Design is also…
-
CleanPro® Softwall Cleanroom Enclosure
This customer needed to enclose a piece of machinery, and CleanPro® was able to provide a solution.
-
CleanPro® Turnkey Cleanroom Install
CleanPro’s turn-key cleanroom solution provided a one-stop, one-contact result for the initial delivery and on-site installation of walls, ceiling grids, electrical systems, flooring, filters, HVAC, and more.
-
Why is Modular Cleanroom Design A Huge Development?
Pre-engineered fabrication consolidates scheduling with minimal disruption and fewer variables. Difficult or expensive upgrades avoid overbearing noise, construction artifacts, and minimize if not eliminate the burden on facility staff for project management.
1 thought on “Modular Cleanrooms for Business Startups & New Product Development”